How to test and compare UV print quality
Testing guide · 4 min read
Record each setup and substrate
Record the model, head version and count, ink, print software, mode, passes and whether white ink is used. Record temperature, measured humidity if available, substrate, paint, cleaning, primer and topcoat. Use specimens from the same substrate batch where possible. When ink systems require different preparation, document each recipe and compare the finished systems on the same substrate type. Consult the exact equipment manual and the safety data sheets for the inks before operating.
Source: DXonJet · Equipment manuals and ink safety data sheets (opens an external site) · J-STAGE · Weather resistance of UV printing on concrete (opens an external site) · Coatings · Primers and color reproduction on MDF (opens an external site)Prepare the file and acceptance criteria
Use the same file and output size, for example a 1 × 1 m target that all the machines can print. Include small text, fine lines, solid patches, gradients and an area that needs opacity. Before printing, define viewing conditions, viewing distance, acceptable defects and the reviewer. Select settings that meet the common quality threshold and log those settings. For edge-critical work, measure the actual clearances between the printable area and wall boundaries on all sides.
Time printing and the complete job
Record elapsed printing time from the first to the last pass for acceptable output, including white passes where used. Also record elapsed job time from on-site preparation through cleaning and pack-down, including track alignment, nozzle checks, reprints and interruptions. Record crew size and person-hours separately. For illustration, 1 m² printed in 20 minutes is 3 m²/h during printing. If the whole job takes 45 minutes, throughput is 1.33 m²/h. Compare each figure only with figures collected the same way.
Source: ZHdK · Logs for two 2023 exhibition jobs (opens an external site)Document quality and defects for another reviewer
Capture a full view and close-ups with a scale, consistent lighting and original image files. Count banding, missing details, positioning errors and reprints. Record the adhesion method, time after printing, control sample and any cleaning or exposure conditions. If measuring color, log the instrument, settings, patches and color difference formula such as ΔE00. ISO 13655 is a reference for spectral measurement and colorimetry in print. Claim conformity only when the applicable requirements have been followed.
Source: ISO 13655:2017 · Scope of spectral measurement and colorimetry (opens an external site) · J-STAGE · Weather resistance of UV printing on concrete (opens an external site) · Nanomaterials · Surface treatment of PMMA and PC (opens an external site)Repeat runs and report the full results
For an initial series, run each configuration three times and vary run order where practical to reduce learning effects. Save timing and outcome for every run, including failures, under the recorded conditions. Report the run count, median and observed range with supporting defect photos. Three runs describe that trial. Log changes to ink batch, substrate, viewing distance or software as a distinct condition.
Source: Google Search · Guidance on writing reviews (opens an external site)Keep an auditable trial record
A record includes the date, operator, setup, substrate, versioned test file, acceptance criteria, run-level table, original images and notes on interruptions. Declare who owns the machine, who funded the trial and who controls publication. Publish field images or contributor material only within the permission granted.
Source: Google Search · Guidance on writing reviews (opens an external site) · WIPO · Copyright FAQ for material available online (opens an external site)Sources for this article
- DXonJet · Equipment manuals and ink safety data sheets (opens an external site)
- J-STAGE · Weather resistance of UV printing on concrete (opens an external site)
- Coatings · Primers and color reproduction on MDF (opens an external site)
- ZHdK · Logs for two 2023 exhibition jobs (opens an external site)
- ISO 13655:2017 · Scope of spectral measurement and colorimetry (opens an external site)
- Nanomaterials · Surface treatment of PMMA and PC (opens an external site)
- Google Search · Guidance on writing reviews (opens an external site)
- WIPO · Copyright FAQ for material available online (opens an external site)
Each link goes to the original page. Checked 20 November 2026.